Softwares

Below follows a selection of software that our locks are  available with. In a case that you do not find the model that fulfills your functional specification please feel free to contact us, we will be glad to offer customized solution just for you . You may also check KGMaster.
In order to download user manual click on software name or article number.

LOCK MODEL
LOCK TYPE
AVAILABLE SOFTWARE
SOFTWARE DESCRIPTION
functions
NOTE
ARTICLE NUMBER
Lock+ Software
EM15-20
DirectDrive
DeadBolt
Solenoid Lock
*Not Standard Footprint
2-users, no Time Delay, function #5
2-users, with Time Delay, function #5
EM25-20
MotorDrive
*Automatic Closing Mode
DeadBolt
MotorLock
*Standard Footprint
2-users, no Time Delay, function #5
2-users, with Time Delay, function #5
EM30-20
MotorDrive
* One-key-to-close mode
DeadBolt
MotorLock
*Standard Footprint
2-users, no Time Delay, function #5
2-users, with Time Delay, function #5
EM20-20
RotoBolt
SwingBolt
MotorLock
*Standard Footprint
2-users, no Time Delay, function #5
2-users, with Time Delay, function #5
EP80-50
ePASS
CamLock
8x8 mm shaft
10-users, no Time Delay, function #5
2-users, with Time Delay, function #5
10-users, with Time Delay, function #5
1 Manager (6 digits), 1 user (4 digits) – Changing Users
1 Manager (6 digits), 1 user (6 digits) – Changing Users
If your annual quantity exceed 2000 electronic units please contact us for presentation of special OEM software.

 

Function Description
Manager Can open, change own code, manage users, program time delay, audit users and lock.
User Can open and change own code
Time Delay Time Delay programmable from 0 (no time delay) to 99 minutes. Open window from 1 to 19 minutes. During time delay enabled LED flashes at two seconds intervals. Open window is indicated by light and sound signal at 1 second intervals alternately (once LED, once beep).
Open Window Open window programmable from 1 to 19 minutes. Open window is indicated by light and sound signal at 1 second intervals alternately (once LED, once beep)
Time Delay Override CIT user Possibility to bypass Time Delay
Dual Mode Two codes required to open the lock.
Silent Alarm Signal Duress signal if last number of code is entered using one number higher
Actual code: 1-2-3-4-5-6
Silent Alarm Code: 1-2-3-4-5-7
*Battery/Alarm I/O box required
Remote Disable Input A remote signal can prevent a lock use.
* Battery/Alarm I/O box required
Dallas i-button Key Shaped Code A Dallas key can be associated to any user during user installation (function #1) by simply entering a Dallas key after the code has been entered. User will then be identified by code plus Dallas key. Multiple keys with the same ID can be programmed (through PC software) and can be supplied for special applications.
Battery Low Warning If battery low (< 6V) lock signals with multiple sound signals during lock usage.
Time penalty When entering code, a time penalty of 5 minutes will be started after the 4th consecutive wrong code entered. During time penalty, LED flashes at 10s interval, no access possible to lock.
Any key pressed during time penalty emits a long beep. After time penalty, two consecutive wrong codes will start it again.
Audit features Users current status can be audited through the keypad with function #7. A « basic audit » file (last 100 openings, no time&date) is recorded on the standard lock board. “Basic audit” can be downloaded to an i-Button on the keypad with function #7. An « extended audit » file (last 500 operations w/time&date) can be implemented on a « satellite » board to be connected to the alarm/battery additional connector on lock standard board. “Extended audit” can only be extracted from the “satellite” board directly to a PC through a dedicated interface.
Test Keypad Enter special function #5.Enter each key once, starting with key ‘1’, then ‘2’, ‘3’, ‘4, … ‘8’, ‘9’, ‘0’. Each key is acknowledged with a double beep. If a key is not recognized, a long beep is emitted after bad key pressed and function is aborted.
Power Supply 9V Battery